Inspect

Inspection Box

Selection

Reference

This denotes the data that is the basis of the inspection. Only one mesh can be selected.

Source(s)

The data that is the target of the inspection. Multiple meshes can be selected.

Run

The inspection results are displayed as a color map on the mesh selected as the Source(s).

The green area, which is a well aligned area, indicates the area closed to the reference. The larger the red or blue area, the larger is the difference.

The region of the color may be changed depending on range Min. and Max.

Notice

Only the mesh selected as the source is shown on the screen.

Color Range Option

Min., Max. Distance

​The range value between the Reference and Source(s), which determines the range of the color map. Depending on the range value between the Reference and Source(s), it determines the range of the color map.

Notice

Min. value cannot be larger than the Max. value in any case.

Distance Type

  • Signed Symmetric Distance:

Depending on the positional relationship between meshes, it is divided into +/- distances, and Min., Max. The magnitudes are set to be equal.

  • Signed Asymmetric Distance:

According to the positional relationship between meshes, it is divided into +/- distance, and Min., Max. values can be set individually.

  • Unsigned Distance:

Regardless of the positional relationship between meshes, it is displayed as a positive(+) distance. The Min. values can be set to at least zero.

Last updated : 2022.02.11 Back to top